PK Q70}* * PDS4_CTLI_1F00_1200.csv"Sort Key","Type","Name","Version","Name Space Id","Description","Steward","Value Type","Minimum Cardinality","Maximum Cardinality","Minimum Value","Maximum Value","Minimum Characters","Maximum Characters","Unit of Measure Type","Specified Unit Id","Attribute Concept","Conceptual Domain"
"ctli:Type_List:1 ","Class","Type_List","1.0.0.0","ctli","The Type List class provides a list of values and their value meanings.","ctli","","","","","","","","","","",""
"ctli:Type_List:2 ctli:type:1 ","Attribute","type","n/a","ctli"," The type attribute provides a character string which uniquely identifies the object. ","ctli","UTF8_Short_String_Collapsed","1","*","Unbounded","Unbounded","1","255","Units_of_None","none","TBD_classConcept","SHORT_STRING"
"ctli:Type_List:2 ctli:type:2 Value:Accelerometer","Value","Accelerometer","",""," An accelerometer measures acceleration -- rate of change of velocity -- in its own rest frame. "
"ctli:Type_List:2 ctli:type:2 Value:Altimeter","Value","Altimeter","",""," An altimeter measures distance above a surface. "
"ctli:Type_List:2 ctli:type:2 Value:Atmospheric Structur","Value","Atmospheric Structure Instrument","",""," An atmospheric structure instrument measures one or more structural properties of an atmosphere. These properties may include -- but are not limited to -- pressure, temperature, density, wind speed, and wind direction. "
"ctli:Type_List:2 ctli:type:2 Value:Camera","Value","Camera","",""," A camera is an optical instrument that captures a still image or a sequence of images on physical media. "
"ctli:Type_List:2 ctli:type:2 Value:Charged Particle Det","Value","Charged Particle Detector","",""," A charged particle detector detects and/or counts charged particles, and provides information about particle properties and distributions. "
"ctli:Type_List:2 ctli:type:2 Value:Dust Analyzer","Value","Dust Analyzer","",""," A dust analyzer measures the size and/or energy distribution of dust particles. "
"ctli:Type_List:2 ctli:type:2 Value:Electric Field Instr","Value","Electric Field Instrument","",""," An electric field instrument measures the direction and/or strength of an electric field. "
"ctli:Type_List:2 ctli:type:2 Value:Gamma Ray Detector","Value","Gamma Ray Detector","",""," A gamma ray detector is an instrument that detects gamma rays. "
"ctli:Type_List:2 ctli:type:2 Value:Gas Analyzer","Value","Gas Analyzer","",""," A gas analyzer measures the concentration of one or more species in a mixture of neutral gases. "
"ctli:Type_List:2 ctli:type:2 Value:Gravimeter","Value","Gravimeter","",""," A gravimeter measures gravitational acceleration. "
"ctli:Type_List:2 ctli:type:2 Value:Imager","Value","Imager","",""," An imager detects and converts information into a digital image. "
"ctli:Type_List:2 ctli:type:2 Value:Imaging Spectrometer","Value","Imaging Spectrometer","",""," An imaging spectrometer acquires a spectrally-resolved image of an object or scene. Two axes of the image correspond to orthogonal spatial dimensions and the third corresponds to wavelength. "
"ctli:Type_List:2 ctli:type:2 Value:Interferometer","Value","Interferometer","",""," An interferometer superposes waves such that constructive and destructive interference results in patterns that can be interpreted as very small displacements at the signal source. "
"ctli:Type_List:2 ctli:type:2 Value:Langmuir Probe","Value","Langmuir Probe","",""," A Langmuir probe consists of one or more electrodes used to determine in-situ plasma properties such as density and temperature from the measured potentials and currents. "
"ctli:Type_List:2 ctli:type:2 Value:Lidar","Value","Lidar","",""," A lidar measures distance to a target by illuminating it with a pulsed laser and measuring the time delay of the reflected signal. "
"ctli:Type_List:2 ctli:type:2 Value:Magnetometer","Value","Magnetometer","",""," A magnetometer measures the direction and/or strength of a magnetic field. "
"ctli:Type_List:2 ctli:type:2 Value:Mass Spectrometer","Value","Mass Spectrometer","",""," A mass spectrometer sorts and counts atoms, ions, and/or molecules based on their masses. "
"ctli:Type_List:2 ctli:type:2 Value:Meteorology","Value","Meteorology","",""," A meteorology instrument measures in situ meteorological conditions. These may include -- but are not limited to -- pressure, temperature, wind speed, and wind direction. "
"ctli:Type_List:2 ctli:type:2 Value:Microphone","Value","Microphone","",""," A microphone converts sound waves into electrical signals. "
"ctli:Type_List:2 ctli:type:2 Value:Microscope","Value","Microscope","",""," A microscope magnifies objects that are too small to be seen with the naked eye. "
"ctli:Type_List:2 ctli:type:2 Value:Mutual Impedance Pro","Value","Mutual Impedance Probe","",""," A mutual impedance probe measures in situ bulk plasma properties at radio frequencies. "
"ctli:Type_List:2 ctli:type:2 Value:Nephelometer","Value","Nephelometer","",""," A nephelometer measures the concentration of suspended (cloud) particulates. "
"ctli:Type_List:2 ctli:type:2 Value:Neutral Particle Det","Value","Neutral Particle Detector","",""," A neutral particle detector detects and/or counts neutral particles, and provides information about particle properties and distributions. "
"ctli:Type_List:2 ctli:type:2 Value:Neutron Detector","Value","Neutron Detector","",""," A neutron detector detects and/or counts neutrons. "
"ctli:Type_List:2 ctli:type:2 Value:Photometer","Value","Photometer","",""," A photometer measures the intensity of electromagnetic radiation over a wavelength range at infrared and shorter wavelengths. "
"ctli:Type_List:2 ctli:type:2 Value:Polarimeter","Value","Polarimeter","",""," A polarimeter measures the polarization of an electromagnetic wave. "
"ctli:Type_List:2 ctli:type:2 Value:Radar","Value","Radar","",""," A radar transmits an electromagnetic wave, then measures amplitude, time delay, frequency shift, phase shift, and/or polarization of the echo from a distant target. "
"ctli:Type_List:2 ctli:type:2 Value:Radio Receiver","Value","Radio Receiver","",""," A radio receiver detects the information in propagating electromagnetic waves collected by an antenna. "
"ctli:Type_List:2 ctli:type:2 Value:Radio Science","Value","Radio Science","",""," Radio science is the use of active and/or passive electromagnetic waves to probe the environment. "
"ctli:Type_List:2 ctli:type:2 Value:Radiometer","Value","Radiometer","",""," A radiometer measures radiant flux (power) of electromagnetic radiation. "
"ctli:Type_List:2 ctli:type:2 Value:Relaxation Sounder","Value","Relaxation Sounder","","","A relaxation sounder determines the properties of a plasma by actively probing at radio frequencies at and near the plasma frequency."
"ctli:Type_List:2 ctli:type:2 Value:Seismometer","Value","Seismometer","",""," A seismometer measures ground motions such as might be caused by earthquakes, volcanic eruptions, or explosions. "
"ctli:Type_List:2 ctli:type:2 Value:Spacecraft Sensor","Value","Spacecraft Sensor","",""," A spacecraft sensor captures information on the status or physical condition of a spacecraft or its components. These may include, but are not limited to, temperatures, mechanical friction, currents, voltages, etc. "
"ctli:Type_List:2 ctli:type:2 Value:Spectrometer","Value","Spectrometer","",""," A spectrometer measures an energy spectrum. "
"ctli:Type_List:2 ctli:type:2 Value:Spectrum Analyzer","Value","Spectrum Analyzer","",""," A spectrum analyzer measures the properties of photons, charged particles, or electrical signals as a function of frequency or energy. "
"ctli:Type_List:2 ctli:type:2 Value:Sub-Surface Tool","Value","Sub-Surface Tool","",""," A sub-surface tool probes the upper few meters of a surface to infer its properties. Examples include (but are not limited to) drills and penetrators. "
"ctli:Type_List:2 ctli:type:2 Value:Surface Tool","Value","Surface Tool","",""," A surface tool physically probes a surface to infer its properties. Examples include (but are not limited to) brush and deployment systems. "
"ctli:Type_List:2 ctli:type:2 Value:Temperature Sensor","Value","Temperature Sensor","","","A temperature sensor measures temperature."
"ctli:Type_List:2 ctli:type:2 Value:Weather Station","Value","Weather Station","",""," A weather station is a suite of instruments that measures in situ meteorological conditions. These may include -- but are not limited to -- pressure, temperature, wind speed and wind direction. "
"ctli:Type_List:2 ctli:type:2 Value:Wind Tunnel","Value","Wind Tunnel","",""," A wind tunnel is used to study the effects of air moving past solid objects. "
"ctli:Type_List:2 ctli:subtype:1 ","Attribute","subtype","n/a","ctli","The subtype attribute provides additional nuance or clarity to the type attribute.","ctli","UTF8_Short_String_Collapsed","0","*","Unbounded","Unbounded","1","255","Units_of_None","none","TBD_classConcept","SHORT_STRING"
PK Qv8 PDS4_CTLI_1F00_1200.sch
Schematron using XPath 2.0
The attribute ctli:type must be equal to one of the following values 'Accelerometer', 'Altimeter', 'Atmospheric Structure Instrument', 'Camera', 'Charged Particle Detector', 'Dust Analyzer', 'Electric Field Instrument', 'Gamma Ray Detector', 'Gas Analyzer', 'Gravimeter', 'Imager', 'Imaging Spectrometer', 'Interferometer', 'Langmuir Probe', 'Lidar', 'Magnetometer', 'Mass Spectrometer', 'Meteorology', 'Microphone', 'Microscope', 'Mutual Impedance Probe', 'Nephelometer', 'Neutral Particle Detector', 'Neutron Detector', 'Photometer', 'Polarimeter', 'Radar', 'Radio Receiver', 'Radio Science', 'Radiometer', 'Relaxation Sounder', 'Seismometer', 'Spacecraft Sensor', 'Spectrometer', 'Spectrum Analyzer', 'Sub-Surface Tool', 'Surface Tool', 'Temperature Sensor', 'Weather Station', 'Wind Tunnel'.
PK Q>
PDS4_CTLI_1F00_1200.xml
urn:nasa:pds:system_bundle:xml_schema:ctli-xml_schema
1.0
PDS4 XML Schema - CTLI V1.2.0.0
1.15.0.0
Product_XML_Schema
2020-10-13
1.0
This is the system generated PDS4 product label for PDS4 XML Schema and Schematron files.
PDS4_CTLI_1F00_1200.xsd
2020-10-13T19:55:43
4209
77
PDS4_CTLI_1F00_1200.xsd
0
XML Schema Version 1.1
This is a PDS4 XML Schema file for the declared namespace.
PDS4_CTLI_1F00_1200.sch
2020-10-13T19:55:43
2833
27
PDS4_CTLI_1F00_1200.sch
0
Schematron ISO/IEC 19757-3:2006
This is the PDS4 Schematron file for the declared namespace. Schematron provides rule-based validation for XML Schema.
PK Qx&y y PDS4_CTLI_1F00_1200.txtPDS4 Local Data Dictionary Processing Report
Configuration:
LDDTool Version 12.0.0
LDD Version Id: 1.2.0.0
LDD Label Version Id: 1.0
LDD Discipline (T/F): true
LDD Namespace URL: http://pds.nasa.gov/pds4/
LDD URN Prefix: urn:nasa:pds:
Time Wed Oct 14 02:55:43 UTC 2020
Common Schema [PDS4_PDS_1F00.xsd]
Common Schematron [PDS4_PDS_1F00.sch]
IM Version Id: 1.15.0.0
IM Namespace Id: pds
IM Label Version Id: 1.21
IM Object Model [UpperModel.pont]
IM Data Dictionary [dd11179.pins]
IM Configuration File [MDPTNConfigClassDisp.xml]
IM Glossary [Glossary.pins]
IM Document Spec [DMDocument.pins]
Parameters:
Input File [/home/runner/work/ldd-ctli/ldd-ctli/src/PDS4_CTLI_IngestLDD.xml]
PDS Processing true
LDD Processing true
Discipline LDD true
Mission LDD false
Write Attr Elements false
Merge with Master false
Summary:
Classes 1
Attributes 2
Associations 2
Error messages 0
Warning messages 0
Information messages 0
Detailed validation messages
Parsed Input - Header:
LDD Name Type_List
LDD Version 1.2.0.0
Full Name Lyle Huber
Steward ctli
Namespace Id ctli
Comment
The Instrument Type List Dictionary provides a set of permissible values and their
value meanings for use by the enumerated attribute type in the Instrument class.
Modification History:
2019-11-14: First version delivered by the Instrument Type Steward Team.
Last Modification Time 2020-03-04T21:00:00Z
PDS4 Merge Flag false
Parsed Input - Attributes:
name type
version 1.15
value data type UTF8_Short_String_Collapsed
description The type attribute provides a character string which uniquely identifies the object.
minimum characters 1
maximum characters 255
name subtype
version 1.15
value data type UTF8_Short_String_Collapsed
description The subtype attribute provides additional nuance or clarity to the type attribute.
Parsed Input - Classes:
name Type_List
description The Type List class provides a list of values and their value meanings.
is abstract false
is choice false
subclass of USER
Associations
local identifier type
minimum occurrences 1
maximum occurrences *
reference type attribute_of
local identifier subtype
minimum occurrences 0
maximum occurrences *
reference type attribute_of
End of Report
PK Q%XT|@ @ PDS4_CTLI_1F00_1200.JSON[
{
"dataDictionary": {
"Title": "PDS4 Data Dictionary" ,
"Version": "1.15.0.0" ,
"Date": "Wed Oct 14 02:55:43 UTC 2020" ,
"Description": "This document is a dump of the contents of the PDS4 Data Dictionary" ,
"classDictionary": [
{
"class": {
"identifier": "0001_NASA_PDS_1.ctli.Type_List" ,
"title": "Type_List" ,
"registrationAuthorityId": "0001_NASA_PDS_1" ,
"nameSpaceId": "ctli" ,
"steward": "ctli" ,
"versionId": "1.0.0.0" ,
"isAbstract": "false" ,
"isDeprecated": "false" ,
"description": "The Type List class provides a list of values and their value meanings."
, "associationList": [
{"association": {
"identifier": "0001_NASA_PDS_1.ctli.Type_List.ctli.type" ,
"title": "type" ,
"assocType": "attribute_of" ,
"isAttribute": "true" ,
"isChoice": "false" ,
"isAny": "false" ,
"groupName": "null" ,
"minimumCardinality": "1" ,
"maximumCardinality": "*" ,
"classOrder": "1010" ,
"attributeId": [
"0001_NASA_PDS_1.ctli.Type_List.ctli.type"
]
}
}
, {"association": {
"identifier": "0001_NASA_PDS_1.ctli.Type_List.ctli.subtype" ,
"title": "subtype" ,
"assocType": "attribute_of" ,
"isAttribute": "true" ,
"isChoice": "false" ,
"isAny": "false" ,
"groupName": "null" ,
"minimumCardinality": "0" ,
"maximumCardinality": "*" ,
"classOrder": "1020" ,
"attributeId": [
"0001_NASA_PDS_1.ctli.Type_List.ctli.subtype"
]
}
}
]
}
}
]
, "attributeDictionary": [
{
"attribute": {
"identifier": "0001_NASA_PDS_1.ctli.Type_List.ctli.subtype" ,
"title": "subtype" ,
"registrationAuthorityId": "0001_NASA_PDS_1" ,
"nameSpaceId": "ctli" ,
"steward": "ctli" ,
"versionId": "1.15" ,
"description": "The subtype attribute provides additional nuance or clarity to the type attribute." ,
"isNillable": "false" ,
"isEnumerated": "false" ,
"isDeprecated": "false" ,
"dataType": "UTF8_Short_String_Collapsed" ,
"dataTypeId": "0001_NASA_PDS_1.pds.UTF8_Short_String_Collapsed" ,
"minimumCharacters": "1" ,
"maximumCharacters": "255" ,
"minimumValue": "Unbounded" ,
"maximumValue": "Unbounded" ,
"pattern": "null" ,
"unitOfMeasure": "null" ,
"unitOfMeasureId": "null" ,
"unitId": "null" ,
"defaultUnitId": "null"
}
}
, {
"attribute": {
"identifier": "0001_NASA_PDS_1.ctli.Type_List.ctli.type" ,
"title": "type" ,
"registrationAuthorityId": "0001_NASA_PDS_1" ,
"nameSpaceId": "ctli" ,
"steward": "ctli" ,
"versionId": "1.15" ,
"description": " The type attribute provides a character string which uniquely identifies the object. " ,
"isNillable": "false" ,
"isEnumerated": "true" ,
"isDeprecated": "false" ,
"dataType": "UTF8_Short_String_Collapsed" ,
"dataTypeId": "0001_NASA_PDS_1.pds.UTF8_Short_String_Collapsed" ,
"minimumCharacters": "1" ,
"maximumCharacters": "255" ,
"minimumValue": "Unbounded" ,
"maximumValue": "Unbounded" ,
"pattern": "null" ,
"unitOfMeasure": "null" ,
"unitOfMeasureId": "null" ,
"unitId": "null" ,
"defaultUnitId": "null"
, "PermissibleValueList": [
{"PermissibleValue": {
"value": "Accelerometer" ,
"valueMeaning": " An accelerometer measures acceleration -- rate of change of velocity -- in its own rest frame. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Altimeter" ,
"valueMeaning": " An altimeter measures distance above a surface. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Atmospheric Structure Instrument" ,
"valueMeaning": " An atmospheric structure instrument measures one or more structural properties of an atmosphere. These properties may include -- but are not limited to -- pressure, temperature, density, wind speed, and wind direction. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Camera" ,
"valueMeaning": " A camera is an optical instrument that captures a still image or a sequence of images on physical media. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Charged Particle Detector" ,
"valueMeaning": " A charged particle detector detects and\/or counts charged particles, and provides information about particle properties and distributions. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Dust Analyzer" ,
"valueMeaning": " A dust analyzer measures the size and\/or energy distribution of dust particles. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Electric Field Instrument" ,
"valueMeaning": " An electric field instrument measures the direction and\/or strength of an electric field. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Gamma Ray Detector" ,
"valueMeaning": " A gamma ray detector is an instrument that detects gamma rays. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Gas Analyzer" ,
"valueMeaning": " A gas analyzer measures the concentration of one or more species in a mixture of neutral gases. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Gravimeter" ,
"valueMeaning": " A gravimeter measures gravitational acceleration. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Imager" ,
"valueMeaning": " An imager detects and converts information into a digital image. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Imaging Spectrometer" ,
"valueMeaning": " An imaging spectrometer acquires a spectrally-resolved image of an object or scene. Two axes of the image correspond to orthogonal spatial dimensions and the third corresponds to wavelength. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Interferometer" ,
"valueMeaning": " An interferometer superposes waves such that constructive and destructive interference results in patterns that can be interpreted as very small displacements at the signal source. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Langmuir Probe" ,
"valueMeaning": " A Langmuir probe consists of one or more electrodes used to determine in-situ plasma properties such as density and temperature from the measured potentials and currents. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Lidar" ,
"valueMeaning": " A lidar measures distance to a target by illuminating it with a pulsed laser and measuring the time delay of the reflected signal. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Magnetometer" ,
"valueMeaning": " A magnetometer measures the direction and\/or strength of a magnetic field. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Mass Spectrometer" ,
"valueMeaning": " A mass spectrometer sorts and counts atoms, ions, and\/or molecules based on their masses. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Meteorology" ,
"valueMeaning": " A meteorology instrument measures in situ meteorological conditions. These may include -- but are not limited to -- pressure, temperature, wind speed, and wind direction. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Microphone" ,
"valueMeaning": " A microphone converts sound waves into electrical signals. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Microscope" ,
"valueMeaning": " A microscope magnifies objects that are too small to be seen with the naked eye. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Mutual Impedance Probe" ,
"valueMeaning": " A mutual impedance probe measures in situ bulk plasma properties at radio frequencies. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Nephelometer" ,
"valueMeaning": " A nephelometer measures the concentration of suspended (cloud) particulates. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Neutral Particle Detector" ,
"valueMeaning": " A neutral particle detector detects and\/or counts neutral particles, and provides information about particle properties and distributions. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Neutron Detector" ,
"valueMeaning": " A neutron detector detects and\/or counts neutrons. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Photometer" ,
"valueMeaning": " A photometer measures the intensity of electromagnetic radiation over a wavelength range at infrared and shorter wavelengths. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Polarimeter" ,
"valueMeaning": " A polarimeter measures the polarization of an electromagnetic wave. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Radar" ,
"valueMeaning": " A radar transmits an electromagnetic wave, then measures amplitude, time delay, frequency shift, phase shift, and\/or polarization of the echo from a distant target. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Radio Receiver" ,
"valueMeaning": " A radio receiver detects the information in propagating electromagnetic waves collected by an antenna. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Radio Science" ,
"valueMeaning": " Radio science is the use of active and\/or passive electromagnetic waves to probe the environment. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Radiometer" ,
"valueMeaning": " A radiometer measures radiant flux (power) of electromagnetic radiation. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Relaxation Sounder" ,
"valueMeaning": "A relaxation sounder determines the properties of a plasma by actively probing at radio frequencies at and near the plasma frequency." ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Seismometer" ,
"valueMeaning": " A seismometer measures ground motions such as might be caused by earthquakes, volcanic eruptions, or explosions. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Spacecraft Sensor" ,
"valueMeaning": " A spacecraft sensor captures information on the status or physical condition of a spacecraft or its components. These may include, but are not limited to, temperatures, mechanical friction, currents, voltages, etc. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Spectrometer" ,
"valueMeaning": " A spectrometer measures an energy spectrum. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Spectrum Analyzer" ,
"valueMeaning": " A spectrum analyzer measures the properties of photons, charged particles, or electrical signals as a function of frequency or energy. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Sub-Surface Tool" ,
"valueMeaning": " A sub-surface tool probes the upper few meters of a surface to infer its properties. Examples include (but are not limited to) drills and penetrators. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Surface Tool" ,
"valueMeaning": " A surface tool physically probes a surface to infer its properties. Examples include (but are not limited to) brush and deployment systems. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Temperature Sensor" ,
"valueMeaning": "A temperature sensor measures temperature." ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Weather Station" ,
"valueMeaning": " A weather station is a suite of instruments that measures in situ meteorological conditions. These may include -- but are not limited to -- pressure, temperature, wind speed and wind direction. " ,
"isDeprecated": "false"
}
}
, {"PermissibleValue": {
"value": "Wind Tunnel" ,
"valueMeaning": " A wind tunnel is used to study the effects of air moving past solid objects. " ,
"isDeprecated": "false"
}
}
]
}
}
]
}
}
]
PK Qq q PDS4_CTLI_1F00_1200.xsd
The Instrument Type List Dictionary provides a set of permissible values and their
value meanings for use by the enumerated attribute type in the Instrument class.
Modification History:
2019-11-14: First version delivered by the Instrument Type Steward Team.
The Type List class provides a list of values
and their value meanings.
This section contains the simpleTypes that provide more constraints
than those at the base data type level. The simpleTypes defined here build on the base data
types. This is another component of the common dictionary and therefore falls within the
common namespace.
The subtype attribute provides additional nuance
or clarity to the type attribute.
The type attribute provides a character string
which uniquely identifies the object.
PK Q=FhP hP PDS4_CTLI_IngestLDD.xml
Type_List
1.2.0.0
Discipline
Lyle Huber
ctli
ctli
The Instrument Type List Dictionary provides a set of permissible values and their
value meanings for use by the enumerated attribute type in the Instrument class.
Modification History:
2019-11-14: First version delivered by the Instrument Type Steward Team.
2020-03-04T21:00:00Z
type
1.0
type
false
Lyle Huber
The type attribute provides a character string which uniquely identifies the object.
true
UTF8_Short_String_Collapsed
1
255
Units_of_None
Accelerometer
An accelerometer measures acceleration -- rate of change of velocity -- in its own rest frame.
Altimeter
An altimeter measures distance above a surface.
Lidar
A lidar measures distance to a target by illuminating it with a pulsed laser
and measuring the time delay of the reflected signal.
English
false
Atmospheric Structure Instrument
An atmospheric structure instrument measures one or more structural properties of an atmosphere.
These properties may include -- but are not limited to -- pressure, temperature,
density, wind speed, and wind direction.
Meteorology
A meteorology instrument measures in situ meteorological conditions.
These may include -- but are not limited to -- pressure, temperature,
wind speed, and wind direction.
English
false
Weather Station
A weather station is a suite of instruments that measures in situ meteorological conditions. These may include -- but are
not limited to -- pressure, temperature, wind speed and wind direction.
English
false
Camera
A camera is an optical instrument that captures a still image or a sequence of images on physical media.
Imager
An imager detects and converts information into a digital image.
English
false
Charged Particle Detector
A charged particle detector detects and/or counts charged particles, and provides information
about particle properties and distributions.
Dust Analyzer
A dust analyzer measures the size and/or energy distribution of dust particles.
Electric Field Instrument
An electric field instrument measures the direction and/or strength of an electric field.
Gamma Ray Detector
A gamma ray detector is an instrument that detects gamma rays.
Gas Analyzer
A gas analyzer measures the concentration of one or more species in a mixture of neutral gases.
Gravimeter
A gravimeter measures gravitational acceleration.
Imager
An imager detects and converts information into a digital image.
Camera
A camera is an optical instrument that captures a still image or a sequence of images on physical media.
English
false
Imaging Spectrometer
An imaging spectrometer acquires a spectrally-resolved image of an object or scene.
Two axes of the image correspond to orthogonal spatial dimensions and the third corresponds to wavelength.
Interferometer
An interferometer superposes waves such that constructive and destructive interference
results in patterns that can be interpreted as very small displacements at the signal source.
Langmuir Probe
A Langmuir probe consists of one or more electrodes used to determine in-situ plasma
properties such as density and temperature from the measured potentials and currents.
Lidar
A lidar measures distance to a target by illuminating it with a pulsed laser
and measuring the time delay of the reflected signal.
Altimeter
An altimeter measures distance above a surface.
English
false
Magnetometer
A magnetometer measures the direction and/or strength of a magnetic field.
Mass Spectrometer
A mass spectrometer sorts and counts atoms, ions, and/or molecules based on their masses.
Meteorology
A meteorology instrument measures in situ meteorological conditions.
These may include -- but are not limited to -- pressure, temperature,
wind speed, and wind direction.
Weather Station
A weather station is a suite of instruments that measures in situ meteorological conditions.
These may include -- but are not limited to -- pressure, temperature, wind speed and wind direction.
English
false
Atmospheric Structure Instrument
An atmospheric structure instrument measures one or more structural properties of an atmosphere.
These properties may include -- but are not limited to -- pressure, temperature,
density, wind speed, and wind direction.
English
false
Microphone
A microphone converts sound waves into electrical signals.
Microscope
A microscope magnifies objects that are too small to be seen with the naked eye.
Mutual Impedance Probe
A mutual impedance probe measures in situ bulk plasma properties at radio frequencies.
Nephelometer
A nephelometer measures the concentration of suspended (cloud) particulates.
Neutral Particle Detector
A neutral particle detector detects and/or counts neutral particles, and provides information
about particle properties and distributions.
Neutron Detector
A neutron detector detects and/or counts neutrons.
Photometer
A photometer measures the intensity of electromagnetic radiation over a wavelength range at infrared and shorter wavelengths.
Polarimeter
A polarimeter measures the polarization of an electromagnetic wave.
Radar
A radar transmits an electromagnetic wave, then measures amplitude, time delay, frequency shift,
phase shift, and/or polarization of the echo from a distant target.
Radio Receiver
A radio receiver detects the information in propagating electromagnetic waves
collected by an antenna.
Radio Science
Radio science is the use of active and/or passive electromagnetic waves to probe the environment.
Radiometer
A radiometer measures radiant flux (power) of electromagnetic radiation.
Relaxation Sounder
A relaxation sounder determines the properties of a plasma by actively probing at radio frequencies at and near the plasma frequency.
Seismometer
A seismometer measures ground motions such as might be caused by earthquakes, volcanic eruptions,
or explosions.
Spacecraft Sensor
A spacecraft sensor captures information on the status or physical condition of a spacecraft or its components.
These may include, but are not limited to, temperatures, mechanical friction, currents, voltages, etc.
Spectrometer
A spectrometer measures an energy spectrum.
Spectrum Analyzer
A spectrum analyzer measures the properties of photons, charged particles, or electrical signals as a function
of frequency or energy.
Sub-Surface Tool
A sub-surface tool probes the upper few meters of a surface to infer its properties.
Examples include (but are not limited to) drills and penetrators.
Surface Tool
A surface tool physically probes a surface to infer its properties.
Examples include (but are not limited to) brush and deployment systems.
Temperature Sensor
A temperature sensor measures temperature.
Weather Station
A weather station is a suite of instruments that measures in situ meteorological conditions. These may include -- but are
not limited to -- pressure, temperature, wind speed and wind direction.
Meteorology
A meteorology instrument measures in situ meteorological conditions.
These may include -- but are not limited to -- pressure, temperature,
wind speed, and wind direction.
English
false
Atmospheric Structure Instrument
An atmospheric structure instrument measures one or more structural properties of an atmosphere.
These properties may include -- but are not limited to -- pressure, temperature,
density, wind speed, and wind direction.
English
false
Wind Tunnel
A wind tunnel is used to study the effects of air moving past solid objects.
subtype
1.0
subtype
false
Lyle Huber
The subtype attribute provides additional nuance or clarity to the type attribute.
false
UTF8_Short_String_Collapsed
Type_List
1.0
Type_List
Lyle Huber
The Type List class provides a list of values and their value meanings.
true
type
attribute_of
1
*
subtype
attribute_of
0
*
PK Q70}* * PDS4_CTLI_1F00_1200.csvPK Qv8 + PDS4_CTLI_1F00_1200.schPK Q>
R6 PDS4_CTLI_1F00_1200.xmlPK Qx&y y QA PDS4_CTLI_1F00_1200.txtPK Q%XT|@ @ L PDS4_CTLI_1F00_1200.JSONPK Qq q ݍ PDS4_CTLI_1F00_1200.xsdPK Q=FhP hP PDS4_CTLI_IngestLDD.xmlPK